Metal roofing ridge flashing lap details pdf

Light gauge metal roof and wall panels installation guide april 2019 1. Fastener pattern at panel termination eave, endlap, valley. The most common flashing for metal roofing is the ridge cap, which is used at the peak. All troughs ending under a ridge or hip flashing of profiled metal roofing must be turned up. The most common flashing for metal roofing is the ridge cap, which is used at the peak of a. Install emseal closure 3 inches back from metal roofing.

This will keep weather out, prevent lifting in high winds, and provide a neat, fin. The most common flashing for standing seam roofing is the ridge cap, which is used at. This residential roofing guide is designed to be utilized as a guide when installing and. Roof flashing details index fd01 interior roof drain detail. The manual is set out in two parts, design and flashing. This manual contains suggestions and guidelines on how to. The metal roofing panels shown in this manual require a min. Just simple 3d animated digital instructions on how to install a ridge cap on a masterrib metal roof.

Purlin spacing must be uniform and carefully measured. The most common flashing for standing seam roofing is the ridge cap, which is used at the peak of a roof where two opposing roof slopes join, and attaches to the roof with zflashing. Below are links to all our products downloadable roof details and drawings. Architectural standing seam install guide best buy metals. Metal roofing instructions for residential roofing installation the following brochure is a stepbystep procedure for reroofing a residence. Standingseam roofing consists of individual panels that run the length of the roof with a high rib up each side of the panels. Roofs there are many factors in designing roofs including. Where the drainage plane is applied over the sheathing, i. Copper flashing, held by a receiver at the top, is locked into a locking strip soldered to the base flashing. Southeastern metals acts only as the seller of roof. Ridge cap wheeling metal deck roofing filtering material rake or gable trim cut and fold ridge cap 3 1 cut and fold side flaps 2 cut and fold top flaps ridge termination. The trim and roofing sheet should be fastened every 12 to 24 inches along the gable edge.

Just simple 3d animated digital instructions on how to install unions masterrib metal roof panels. It is stressed that the detail applies only to metal roofing. Tuffrib install guide page 2 of 31 important notice this manual contains suggestions and guidelines on how to install panels and trim details. Universal closure should be placed between ridge cap and roof panels. If you have any questions about a product please dont hesitate to call us, we will help you get your roofing job done right the first time. Extend flashings 46 beyond the building, cut along the bend lines, apply sealant, and fold the side flaps in and the top flaps down to cap off. This article describes metal roof flashing and sealing products and installation details for exposedfastener metal roof systems. Tuffrib metal roofing can be separated from the moisture barrier. Recently, the national tile roofing manufacturers association ntrma changed its name to tile.

Thompson metals recommends the use of an eave flashing with butyl sealant tape above and. Also for exposed fastener panels, wall panels, tiles, soffit, fascia, copping. Mbbur 20 raised perimeter edge with metal cap fascia flashing detail. Corrugated detail manual semco southeastern metals. Sarnaclad metal flashing crosssection detail drawing pdf pdf 204 kb. Metal roofing panels are slippery when wet, dusty, frosty, or oily do not attempt to walk on a metal roof under these conditions. Where flashings need to be sitebuilt from sheet metal, or flashing membranes, the finished installation must follow the fundamental flashing rules of down and out. Ridge cap wheeling metal deck roofing filtering material rake or gable trim cut and fold ridge cap 3. Masterrib is a 36 wide 5 rib panel very common on residential.

Installation details shown also apply to panelloc and cd2000 profiles. Florida building code allows a minimum pitch of 212 for grand rib3 panels as long as lap screws and sealant are applied to the laps to prevent water from siphoning over the ribs see fig. Factors affecting waterproof and drainage capacity of the laps of a profile include. There is such a wide variety of types and styles of products out there, how do you determine what. Get free 2day shipping on qualified roof flashing products or buy building materials department products today with buy online pick up in store. Other flashings include gable trim, which runs up the sloped ends of the roof, and drip edge or eave trim.

We offer exposed fastener and concealed fastener panels. Modifications are the responsibility of the designeruser and should take into account climate. We also provide a master index to this topic, or you can try the page top or bottom search box as a quick way to find information you need. Use only those accessories specifically designed for use with this product. Tuff rib panel installation specifications baker metal works. The most common flashing for standing seam roofing is the ridge cap, which is used at the peak of a roof where two opposing roof slopes join, and attaches to the roof with z flashing. Supplemental installation details aep span produces performance rated architectural metal wall and metal roof panels for commercial, industrial and residential applications. How to install ridge caps for metal roofing home guides. Typical saddle flashing detail 36 valley felt left side. The most common flashing for standing seam roofing is the ridge cap, which is used at the peak. This style of metal roofing panels requires a certain degree of pitch to ensure proper water drainage. The final touch when installing a metal roof is to install a metal roof ridge cap.

The metal roof system as described within this manual is classified as a. By knowing you have access to all of the right information from proper storage and installation instructions to trim and flashing details, you can be confident installing your fabral materials. The most common flashing for metal roofing is the ridge cap, which is used at the peak of a roof. Fastener selection will vary depending on type and thickness of substrate. Clay and concrete tiles must have a ridge tile as shown in e2as1 figure 23, bedded in mortar with. This is a length of metal flashing shaped to cover the roof peak that you screw to the ridges on the metal roofing.

Detail manual and guide to reeds metals products residential roofing and siding. Thompson architectural metals 8 2483456 thompson architectural metals. Typical roofing details pdf typical roofing details autocad typical roofing details pdf files. Supplemental installation details architectural metal. The nrca national roofing contractors association roofing manual. Tpa221 through wall scupper isometric tpa222 gravel stop. How to install unions masterrib metal roofing panels. To provide a drip edge, allow an overhang of 1 to 2 inches at the eave. Metal tile roofs must be installed with preformed ridge caps of 35 mm over 40 mm minimum metal tile upstands as detailed in e2as1 figure 34. Panelloc plus installation details central states mfg. Light gauge metal roof and wall panels asc building products. How to design and detail steel clad roofs and walls. For overall roof and wall design, refer to the lysaght roofing. Tpa403 expansion joint wall flashing detail tpa501 curb flashing detail using coated metal tpa502 curb flashing detail tpa510 drain flashing detail 8.

This standard details manual, aka the blue book, is the right tool to have at your fingertips. Metal flashing and trim should be installed with sealed end laps that allow for. Peak ridge detail adhered system detail drawing pdf pdf 192 kb. Corten roofing has a unique look and naturally oxidizing finish that make it especially desirable for many architectural projects.

In applications requiring a panel endlap, please refer to the detailed. Endlap flashings a minimum of 6 and seal the lap joints with sealant. It is the responsibility of the bbm customer, installer, andor designer to ensure that the details meet particular building requirements to assure weathertightness. Great care must be taken to use the proper flashings and screws to insure a perfect, long lasting, leak proof roof. Metal roof installation manual metal roofing alliance. If these products are to be used in cyclonic areas as defined in as 1170. The most common flashing for standing seam roofing is the ridge cap, which is used at the peak of a. The enclosed roofing system information and details are a design aid and do not represent all conditions. Metal roofing specifications cad pdf drawings testing bim. At the gable edge, use a gable or sidewall flashing. Arcat free architectural cad drawings, blocks and details for download in dwg and pdf formats for use with autocad and other 2d and 3d design software. Cad details document name pdf dwg download all cad construction details 37.

An insiders guide to metal roofing at a glance, the metal roofing industry can seem a bit overwhelming. This will keep weather out, prevent lifting in high winds, and provide a neat, finished appearance. Get free 2day shipping on qualified metal roofing products or buy building materials department products today with buy online pick up in store. Normal installation procedures for roofing and flashing. Metal roofing instructions for residential roofing.

7 627 683 1498 795 198 1054 1466 1529 488 1513 672 652 969 796 525 693 633 329 446 1077 562 97 415 1149 362 18 549 511 337 94 506 485